PLP-6EAE / SLP-2FAE
3D i-see Sensor Grille
The PLP-6EAE / SLP-2FAE
3D i-see Sensor Grille is available for Mr Slim SLZ-M / PLA-ZM / PLA-M and City Multi VRF PLFY-M-VEM / PLFY-P-VFM-E range of ceiling cassettes.
Key Features & Benefits
360º highly accurate sensor Human body temperature, room occupancy and position detection Energy saving modes Direct / indirect vane settings PAR-41MAA or PAR-SL101-E controllers required
3D i-see Sensor Technology
The Mitsubishi Electric 3D i-see Sensor is one of the most advanced available on the market. It is uniquely embedded in the grille and offers the very best demand control of air conditioning available.
The sensor is able to detect not only if a space is occupied, but also how many people are present. Heating and cooling are adjusted to the exact requirements of occupants – while also ensuring energy efficiency.
8 sensors rotate a
full 360º in 3 minute
intervals
Detects position and
number of people
Detects body and
floor temperature
Detect number of people to save energy
Room occupancy energy-saving mode
Sensors detect the number of people in the room to calculate the occupancy rate in order to save air-conditioning power. Air-conditioning power equivalent to 1°C is saved during both cooling and heating operation at an occupancy rate of ~30%.
No occupancy energy-saving mode
The system is switched to a preset power-saving mode if room is unoccupied. If the room remains unoccupied for more than 60min, air-conditioning power equivalent to 2°C is saved during both cooling and heating operation.
No occupancy Auto-OFF mode
When the room remains unoccupied for a preset period of time, the air conditioner turns off automatically, providing power savings.
Detects position of people and combines with seasonal air flow to save energy
When cooling
By automatically switching between ventilation and cooling, saves energy while keeping a comfortable effective temperature. When a pre-set temperature is reached, the air conditioning unit switches to swing fan operation to maintain an effective temperature
When heating
The unit automatically switches between circulator and heating. Heat that accumulates near the ceiling is reused. When a pre-set temperature is reached the air conditioner blows air in the horizontal direction and pushes down the gathered warm air to people’s height.
With the 3D i-see Sensor, it is possible to choose to block or not block the wind for each vane, allowing for direct/indirect air flow towards room occupants. This setting can be accessed via the controller.
Defrost with 3D i-see sensor
If the 3D i-see sensor detects no people or activity, the system actively goes into defrost if required. Occupants wont experience the effects of the system defrost as a result of this feature. In situations where defrost is required while heating, the system will go into defrost even if rooms are occupied. This feature can be accessed via PAR-41MAA Controller.
Ceiling PAR-41MAA PAR-SL101A-E
Cassette Wired Remote Controller Wireless controller
Telephone: 01707 282880
email: air.conditioning@meuk.mee.com
les.mitsubishielectric.co.uk
@meuk_les Mitsubishi Electric Living Mitsubishi Electric mitsubishielectricuk_les Mitsubishi Electric Living thehub.mitsubishielectric.co.uk
@green_gateway Environmental Systems UK Cooling and Heating UK Environmental Systems UK
UNITED KINGDOM Mitsubishi Electric Europe Living Environment Systems Division, Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England. Telephone: 01707 282880 Fax: 01707 278881
IRELAND Mitsubishi Electric Europe, Westgate Business Park, Ballymount, Dublin 24, Ireland. Telephone: (01) 419 8800 Fax: (01) 419 8890 International code: (003531)
Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2021. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
Note: The fuse rating is for guidance only. Please refer to the relevant databook for detailed specification. It is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation and site specific conditions. Mitsubishi Electric’s air conditioning equipment and heat pump systems contain a fluorinated greenhouse gas, R410A (GWP:2088), R32 (GWP:675), R407C (GWP:1774), R134a (GWP:1430), R513A (GWP:631), R454B (GWP:466), R1234ze (GWP:7) or R1234yf (GWP:4). *These GWP values are based on Regulation (EU) No 517/2014 from IPCC 4th edition. In case of Regulation (EU) No.626/2011 from IPCC 3rd edition, these are as follows. R410A (GWP:1975), R32 (GWP:550), R407C (GWP:1650) or R134a (GWP:1300).
Effective as of October 2021
greengateway.mitsubishielectric.co.uk
:reference
https://library.mitsubishielectric.co.uk/